Risk | Medium |
Patch available | YES |
Number of vulnerabilities | 1 |
CVE-ID | CVE-2019-5278 |
CWE-ID | CWE-125 |
Exploitation vector | Network |
Public exploit | N/A |
Vulnerable software |
CampusInsight Server applications / SCADA systems |
Vendor | Huawei |
Security Bulletin
This security bulletin contains one medium risk vulnerability.
EUVDB-ID: #VU23395
Risk: Medium
CVSSv4.0: 4.9 [CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/U:Green]
CVE-ID: CVE-2019-5278
CWE-ID:
CWE-125 - Out-of-bounds read
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to perform a denial of service (DoS) attack.
The vulnerability exists due to a boundary condition in the Advanced Packages feature of the Gauss100 OLTP database. A remote authenticated attacker with permission to execute advanced packages can send elaborate SQL statements to the database, trigger out-of-bounds read error and cause the database to crash.
Install updates from vendor's website.
Vulnerable software versionsCampusInsight: V100R019C00
CPE2.3 External linkshttp://www.huawei.com/en/psirt/security-advisories/huawei-sa-20191204-01-gauss100-en
Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote authenticated user via the Internet.
How the attacker can exploit this vulnerability?
The attacker would have to send a specially crafted request to the affected application in order to exploit this vulnerability.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.