SB2021111820 - Multiple vulnerabilities in Schneider Electric GUIcon



SB2021111820 - Multiple vulnerabilities in Schneider Electric GUIcon

Published: November 18, 2021

Security Bulletin ID SB2021111820
Severity
High
Patch available
NO
Number of vulnerabilities 3
Exploitation vector Remote access
Highest impact Code execution

Breakdown by Severity

High 67% Medium 33%
  • Low
  • Medium
  • High
  • Critical

Description

This security bulletin contains information about 3 secuirty vulnerabilities.


1) Out-of-bounds write (CVE-ID: CVE-2021-22807)

The vulnerability allows a remote attacker to compromise vulnerable system.

The vulnerability exists due to a boundary error when a malicious *.gd1 configuration file is loaded into the GUIcon tool. A remote attacker can trigger out-of-bounds write and execute arbitrary code on the target system.


2) Use-after-free (CVE-ID: CVE-2021-22808)

The vulnerability allows a remote attacker to compromise vulnerable system.

The vulnerability exists due to a use-after-free error when a malicious *.gd1 configuration file is loaded into the GUIcon tool. A remote attacker can execute arbitrary code on the target system.


3) Out-of-bounds read (CVE-ID: CVE-2021-22809)

The vulnerability allows a remote attacker to gain access to potentially sensitive information.

The vulnerability exists due to a boundary condition when a malicious *.gd1 configuration file is loaded into the GUIcon tool. A remote attacker can trigger out-of-bounds read error and read contents of memory on the system or perform a denial of service (DoS) attack.


Remediation

Cybersecurity Help is not aware of any official remediation provided by the vendor.