Risk | Medium |
Patch available | YES |
Number of vulnerabilities | 1 |
CVE-ID | CVE-2021-4034 |
CWE-ID | CWE-20 |
Exploitation vector | Local |
Public exploit | Vulnerability #1 is being exploited in the wild. |
Vulnerable software |
SINUMERIK Edge Server applications / SCADA systems SCALANCE LPE9403 Hardware solutions / Routers & switches, VoIP, GSM, etc |
Vendor | Siemens |
Security Bulletin
This security bulletin contains one medium risk vulnerability.
EUVDB-ID: #VU60007
Risk: Medium
CVSSv4.0: 8.5 [CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:A/U:Green]
CVE-ID: CVE-2021-4034
CWE-ID:
CWE-20 - Improper input validation
Exploit availability: Yes
DescriptionThe vulnerability allows a local user to escalate privileges on the system.
The vulnerability exists due to improper handling of the calling parameters count in the pkexec setuid binary, which causes the binary to execute environment variables as commands. A local user can craft environment variables in a way that they will be processed and executed by pkexec and execute arbitrary commands on the system as root.
Install update from vendor's website.
Vulnerable software versionsSINUMERIK Edge: before 3.3.0
SCALANCE LPE9403: before 2.0
CPE2.3 External linkshttps://cert-portal.siemens.com/productcert/txt/ssa-330556.txt
Q & A
Can this vulnerability be exploited remotely?
No. This vulnerability can be exploited locally. The attacker should have authentication credentials and successfully authenticate on the system.
How the attacker can exploit this vulnerability?
The attacker would have to send a specially crafted request to the affected application in order to exploit this vulnerability.
The attacker would have to login to the system and perform certain actions in order to exploit this vulnerability.
Is there known malware, which exploits this vulnerability?
Yes. This vulnerability is being exploited in the wild.