Security Bulletin
This security bulletin contains one low risk vulnerability.
EUVDB-ID: #VU34100
Risk: Low
CVSSv4.0: 5.9 [CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Clear]
CVE-ID: CVE-2020-7460
CWE-ID:
CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Exploit availability: No
DescriptionThe vulnerability allows a local user to escalate privileges on the system.
The vulnerability exists due to the sendmsg system call in the compat32 subsystem on 64-bit platforms has a time-of-check to time-of-use issue. A local user can tun a specially crafted program from userspace and modify control message headers after they are validation.
Successful exploitation of the vulnerability may allow an attacker to escalate privileges on the system.
Install update from vendor's website.
Vulnerable software versionsEMC Isilon OneFS: All versions
PowerScale OneFS: 9.0.0 - 9.1.0
CPE2.3Q & A
Can this vulnerability be exploited remotely?
No. This vulnerability can be exploited locally. The attacker should have authentication credentials and successfully authenticate on the system.
Is there known malware, which exploits this vulnerability?