Risk | Low |
Patch available | YES |
Number of vulnerabilities | 1 |
CVE-ID | CVE-2022-31808 |
CWE-ID | CWE-20 |
Exploitation vector | Local |
Public exploit | N/A |
Vulnerable software |
SiPass integrated AC5102 Other software / Other software solutions SiPass integrated ACC-AP Other software / Other software solutions |
Vendor | Siemens |
Security Bulletin
This security bulletin contains one low risk vulnerability.
EUVDB-ID: #VU72389
Risk: Low
CVSSv4.0: 5.9 [CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Clear]
CVE-ID: CVE-2022-31808
CWE-ID:
CWE-20 - Improper input validation
Exploit availability: No
DescriptionThe vulnerability allows a local user to escalate privileges on the system.
The vulnerability exists due to insufficient validation of user-supplied input in the telnet command line interface. A local user can pass specially crafted input to the application and execute arbitrary commands on the target system with elevated privileges.
MitigationInstall updates from vendor's website.
Vulnerable software versionsSiPass integrated AC5102: before 2.85.44
SiPass integrated ACC-AP: before 2.85.43
CPE2.3https://cert-portal.siemens.com/productcert/pdf/ssa-658793.pdficsa-23-047-05
Q & A
Can this vulnerability be exploited remotely?
No. This vulnerability can be exploited locally. The attacker should have authentication credentials and successfully authenticate on the system.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.