Risk | Medium |
Patch available | YES |
Number of vulnerabilities | 1 |
CVE-ID | CVE-2022-27490 |
CWE-ID | CWE-200 |
Exploitation vector | Network |
Public exploit | N/A |
Vulnerable software |
FortiManager Server applications / IDS/IPS systems, Firewalls and proxy servers FortiAnalyzer Server applications / IDS/IPS systems, Firewalls and proxy servers FortiPortal Server applications / IDS/IPS systems, Firewalls and proxy servers FortiSwitch Hardware solutions / Routers & switches, VoIP, GSM, etc |
Vendor | Fortinet, Inc |
Security Bulletin
This security bulletin contains one medium risk vulnerability.
EUVDB-ID: #VU75021
Risk: Medium
CVSSv3.1: 5.7 [CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:U/RL:O/RC:C]
CVE-ID: CVE-2022-27490
CWE-ID:
CWE-200 - Information exposure
Exploit availability: No
DescriptionThe vulnerability allows a remote user to gain access to potentially sensitive information.
The vulnerability exists due to excessive data output by the application via the "diagnose debug" commands. A remote user can gain unauthorized access to sensitive information on the system.
MitigationInstall updates from vendor's website.
Vulnerable software versionsFortiManager: 5.6.0 - 6.0.4
FortiAnalyzer: 5.6.0 - 6.0.4
FortiPortal: 4.1.0 - 6.0.9
FortiSwitch: 6.0.0 - 7.0.4
CPE2.3http://fortiguard.com/psirt/FG-IR-18-232
Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote authenticated user via the Internet.
How the attacker can exploit this vulnerability?
The attacker would have to send a specially crafted request to the affected application in order to exploit this vulnerability.
Is there known malware, which exploits this vulnerability?