Risk | Medium |
Patch available | YES |
Number of vulnerabilities | 1 |
CVE-ID | CVE-2023-29054 |
CWE-ID | CWE-326 |
Exploitation vector | Local network |
Public exploit | N/A |
Vulnerable software |
SCALANCE X200-4P IRT Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE X201-3P IRT Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE X201-3P IRT PRO Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE X202-2IRT Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE X202-2P IRT Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE X202-2P IRT PRO Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE X204IRT Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE X204IRT PRO Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE XF201-3P IRT Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE XF202-2P IRT Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE XF204-2BA IRT Hardware solutions / Routers & switches, VoIP, GSM, etc SCALANCE XF204IRT Hardware solutions / Routers & switches, VoIP, GSM, etc SIPLUS NET SCALANCE X202-2P IRT Hardware solutions / Routers & switches, VoIP, GSM, etc |
Vendor | Siemens |
Security Bulletin
This security bulletin contains one medium risk vulnerability.
EUVDB-ID: #VU75031
Risk: Medium
CVSSv4.0: 2 [CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:A/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Green]
CVE-ID: CVE-2023-29054
CWE-ID:
CWE-326 - Inadequate Encryption Strength
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to compromise the target system.
The vulnerability exists due to the SSH server is configured to offer weak ciphers by default. A remote attacker on the local network can perform a man-in-the-middle attack to read and modify any data passed over the connection between legitimate clients and the affected device.
MitigationInstall updates from vendor's website.
Vulnerable software versionsSCALANCE X200-4P IRT: before 5.5.2
SCALANCE X201-3P IRT: before 5.5.2
SCALANCE X201-3P IRT PRO: before 5.5.2
SCALANCE X202-2IRT: before 5.5.2
SCALANCE X202-2P IRT: before 5.5.2
SCALANCE X202-2P IRT PRO: before 5.5.2
SCALANCE X204IRT: before 5.5.2
SCALANCE X204IRT PRO: before 5.5.2
SCALANCE XF201-3P IRT: before 5.5.2
SCALANCE XF202-2P IRT: before 5.5.2
SCALANCE XF204-2BA IRT: before 5.5.2
SCALANCE XF204IRT: before 5.5.2
SIPLUS NET SCALANCE X202-2P IRT: before 5.5.2
CPE2.3https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf
Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the local network (LAN).
How the attacker can exploit this vulnerability?
The attacker would have to send a specially crafted request to the affected device in order to exploit this vulnerability.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.