Risk | High |
Patch available | YES |
Number of vulnerabilities | 3 |
CVE-ID | CVE-2022-32166 CVE-2022-4337 CVE-2022-4338 |
CWE-ID | CWE-125 CWE-191 |
Exploitation vector | Network |
Public exploit | N/A |
Vulnerable software |
SUSE Linux Enterprise Server 12 SP2 BCL Operating systems & Components / Operating system SUSE Linux Enterprise Server 12 Operating systems & Components / Operating system SUSE Linux Enterprise High Performance Computing 12 Operating systems & Components / Operating system openvswitch-dpdk-debuginfo Operating systems & Components / Operating system package or component openvswitch-dpdk-switch Operating systems & Components / Operating system package or component openvswitch-switch-debuginfo Operating systems & Components / Operating system package or component openvswitch-debugsource Operating systems & Components / Operating system package or component openvswitch Operating systems & Components / Operating system package or component openvswitch-dpdk Operating systems & Components / Operating system package or component openvswitch-debuginfo Operating systems & Components / Operating system package or component openvswitch-dpdk-debugsource Operating systems & Components / Operating system package or component openvswitch-dpdk-switch-debuginfo Operating systems & Components / Operating system package or component openvswitch-switch Operating systems & Components / Operating system package or component |
Vendor | SUSE |
Security Bulletin
This security bulletin contains information about 3 vulnerabilities.
EUVDB-ID: #VU68717
Risk: Medium
CVSSv4.0: 6.6 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/U:Green]
CVE-ID: CVE-2022-32166
CWE-ID:
CWE-125 - Out-of-bounds read
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to perform a denial of service (DoS) attack.
The vulnerability exists due to a boundary condition within the minimasks() function in flow.c. A remote attacker can pass specially crafted data to the application, trigger an out-of-bounds read error and crash the service.
Update the affected package openvswitch to the latest version.
Vulnerable software versionsSUSE Linux Enterprise Server 12 SP2 BCL: 12-SP2
SUSE Linux Enterprise Server 12: SP2
SUSE Linux Enterprise High Performance Computing 12: SP2
openvswitch-dpdk-debuginfo: before 2.5.11-25.34.1
openvswitch-dpdk-switch: before 2.5.11-25.34.1
openvswitch-switch-debuginfo: before 2.5.11-25.34.1
openvswitch-debugsource: before 2.5.11-25.34.1
openvswitch: before 2.5.11-25.34.1
openvswitch-dpdk: before 2.5.11-25.34.1
openvswitch-debuginfo: before 2.5.11-25.34.1
openvswitch-dpdk-debugsource: before 2.5.11-25.34.1
openvswitch-dpdk-switch-debuginfo: before 2.5.11-25.34.1
openvswitch-switch: before 2.5.11-25.34.1
CPE2.3https://www.suse.com/support/update/announcement/2023/suse-su-20232259-1/
Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU70471
Risk: Medium
CVSSv4.0: 1.7 [CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:L/SC:N/SI:N/SA:N/E:U/U:Green]
CVE-ID: CVE-2022-4337
CWE-ID:
CWE-125 - Out-of-bounds read
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to gain access to potentially sensitive information or perform a denial of service (DoS) attack.
The vulnerability exists due to a boundary condition when parsing Auto Attach TLV. A remote attacker can send specially crafted LLDP messages to the affected system, trigger an out-of-bounds read error and read contents of memory on the system of perform a denial of service (DoS) attack.
Update the affected package openvswitch to the latest version.
Vulnerable software versionsSUSE Linux Enterprise Server 12 SP2 BCL: 12-SP2
SUSE Linux Enterprise Server 12: SP2
SUSE Linux Enterprise High Performance Computing 12: SP2
openvswitch-dpdk-debuginfo: before 2.5.11-25.34.1
openvswitch-dpdk-switch: before 2.5.11-25.34.1
openvswitch-switch-debuginfo: before 2.5.11-25.34.1
openvswitch-debugsource: before 2.5.11-25.34.1
openvswitch: before 2.5.11-25.34.1
openvswitch-dpdk: before 2.5.11-25.34.1
openvswitch-debuginfo: before 2.5.11-25.34.1
openvswitch-dpdk-debugsource: before 2.5.11-25.34.1
openvswitch-dpdk-switch-debuginfo: before 2.5.11-25.34.1
openvswitch-switch: before 2.5.11-25.34.1
CPE2.3https://www.suse.com/support/update/announcement/2023/suse-su-20232259-1/
Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.
EUVDB-ID: #VU70459
Risk: High
CVSSv4.0: 7.2 [CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber]
CVE-ID: CVE-2022-4338
CWE-ID:
CWE-191 - Integer underflow
Exploit availability: No
DescriptionThe vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to integer underflow when parsing Auto Attach TLV. A remote attacker can send specially crafted LLDP messages to the affected system, trigger an integer underflow and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
Note, by default interfaces are not configured to process LLDP messages.
Update the affected package openvswitch to the latest version.
Vulnerable software versionsSUSE Linux Enterprise Server 12 SP2 BCL: 12-SP2
SUSE Linux Enterprise Server 12: SP2
SUSE Linux Enterprise High Performance Computing 12: SP2
openvswitch-dpdk-debuginfo: before 2.5.11-25.34.1
openvswitch-dpdk-switch: before 2.5.11-25.34.1
openvswitch-switch-debuginfo: before 2.5.11-25.34.1
openvswitch-debugsource: before 2.5.11-25.34.1
openvswitch: before 2.5.11-25.34.1
openvswitch-dpdk: before 2.5.11-25.34.1
openvswitch-debuginfo: before 2.5.11-25.34.1
openvswitch-dpdk-debugsource: before 2.5.11-25.34.1
openvswitch-dpdk-switch-debuginfo: before 2.5.11-25.34.1
openvswitch-switch: before 2.5.11-25.34.1
CPE2.3https://www.suse.com/support/update/announcement/2023/suse-su-20232259-1/
Q & A
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.