Multiple vulnerabilities in Siemens OPC UA



Risk High
Patch available YES
Number of vulnerabilities 2
CVE-ID CVE-2024-42513
CVE-2024-42512
CWE-ID CWE-305
CWE-208
Exploitation vector Network
Public exploit Public exploit code for vulnerability #2 is available.
Vulnerable software
SINUMERIK Edge
Server applications / SCADA systems

SIMATIC IPC DiagMonitor
Server applications / SCADA systems

SIMATIC WinCC Unified
Server applications / SCADA systems

SIMATIC BRAUMAT
Other software / Other software solutions

SIMATIC Energy Manager PRO
Other software / Other software solutions

SIMATIC SISTAR
Other software / Other software solutions

Totally Integrated Automation Portal (TIA Portal)
Other software / Other software solutions

SIMATIC WinCC
Hardware solutions / Firmware

SIMIT Simulation Platform
Hardware solutions / Firmware

Vendor Siemens

Security Bulletin

This security bulletin contains information about 2 vulnerabilities.

1) Authentication Bypass by Primary Weakness

EUVDB-ID: #VU105635

Risk: High

CVSSv4.0: 8 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U/U:Amber]

CVE-ID: CVE-2024-42513

CWE-ID: CWE-305 - Authentication Bypass by Primary Weakness

Exploit availability: No

Description

The vulnerability allows a remote attacker to bypass authentication process.

The vulnerability exists due to insufficient access control in the OPC UA .NET Standard Stack. A remote attacker can bypass application authentication when using HTTPS endpoints.

Mitigation

Install updates from vendor's website.

Vulnerable software versions

SINUMERIK Edge: All versions

SIMATIC BRAUMAT: 8.0 SP1

SIMATIC Energy Manager PRO: 7.2 Update 6 - 7.5

SIMATIC IPC DiagMonitor: All versions

SIMATIC SISTAR: 8.0 SP1

Totally Integrated Automation Portal (TIA Portal): 18 - 19

SIMATIC WinCC: before 8.0 Update 3

SIMATIC WinCC Unified: before 19 Update 4

CPE2.3 External links

https://cert-portal.siemens.com/productcert/txt/ssa-858251.txt


Q & A

Can this vulnerability be exploited remotely?

Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.

How the attacker can exploit this vulnerability?

The attacker would have to send a specially crafted request to the affected application in order to exploit this vulnerability.

Is there known malware, which exploits this vulnerability?

No. We are not aware of malware exploiting this vulnerability.

2) Information Exposure Through Timing Discrepancy

EUVDB-ID: #VU105636

Risk: High

CVSSv4.0: 8.1 [CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:P/U:Amber]

CVE-ID: CVE-2024-42512

CWE-ID: CWE-208 - Information Exposure Through Timing Discrepancy

Exploit availability: Yes

Description

The vulnerability allows a remote attacker to compromise the target system.

The vulnerability exists due to the an exploitable timing discrepancy issue in the OPC UA .NET Standard Stack. A remote attacker can bypass application authentication when the deprecated Basic128Rsa15 security policy is enabled.

Mitigation

Install updates from vendor's website.

Vulnerable software versions

SIMATIC Energy Manager PRO: 7.2 Update 6 - 7.5

SIMIT Simulation Platform: All versions

Totally Integrated Automation Portal (TIA Portal): 19

CPE2.3 External links

https://cert-portal.siemens.com/productcert/txt/ssa-858251.txt


Q & A

Can this vulnerability be exploited remotely?

Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.

How the attacker can exploit this vulnerability?

The attacker would have to send a specially crafted request to the affected application in order to exploit this vulnerability.

Is there known malware, which exploits this vulnerability?

No. We are not aware of malware exploiting this vulnerability. However, proof of concept for this vulnerability is available.