SB2025071850 - Memory leak in Junos OS Evolved and Juniper Junos OS



SB2025071850 - Memory leak in Junos OS Evolved and Juniper Junos OS

Published: July 18, 2025

Security Bulletin ID SB2025071850
Severity
Low
Patch available
YES
Number of vulnerabilities 1
Exploitation vector Local access
Highest impact Denial of service

Breakdown by Severity

Low 100%
  • Low
  • Medium
  • High
  • Critical

Description

This security bulletin contains information about 1 security vulnerability.


1) Memory leak (CVE-ID: CVE-2025-52986)

The vulnerability allows a local user to perform a denial of service (DoS) attack.

The vulnerability exists due to missing release of memory after effective lifetime error in the routing protocol daemon (rpd). A local user can cause an impact to the availability of the device.

When RIB sharding is enabled and a user executes 1 of several routing related 'show' commands, a certain amount of memory is leaked.

When all available memory has been consumed rpd will crash and restart.


Remediation

Install update from vendor's website.