Vulnerability identifier: #VU105625
Vulnerability risk: High
CVSSv4.0: 4 [CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber]
CVE-ID: CVE-2025-23396
CWE-ID:
CWE-787
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
Teamcenter Visualization
Other software /
Other software solutions
Tecnomatix Plant Simulation
Server applications /
SCADA systems
Vendor: Siemens
Description
The vulnerability allows a remote attacker to compromise vulnerable system.
The vulnerability exists due to a boundary error when processing untrusted input. A remote attacker can create a specially crafted WRL file, trick the victim into opening it using the affected software, trigger an out-of-bounds write and execute arbitrary code on the target system.
Mitigation
Install updates from vendor's website.
Vulnerable software versions
Teamcenter Visualization: before 14.3.0.13
Tecnomatix Plant Simulation: before 2302.0021
External links
https://cert-portal.siemens.com/productcert/html/ssa-050438.html
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.