Vulnerability identifier: #VU23597
Vulnerability risk: High
CVSSv4.0: 5.7 [CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N/E:U/U:Amber]
CVE-ID:
CWE-ID:
CWE-22
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
SiNVR 3 Central Control Server (CCS)
Server applications /
SCADA systems
Vendor: Siemens
Description
The vulnerability allows a remote attacker to perform directory traversal attacks.
The vulnerability exists due to input validation error when processing directory traversal sequences in the XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. A remote authenticated attacker can send a specially crafted HTTP request and list arbitrary directories or read files outside of the CCS application context.
Mitigation
Cybersecurity Help is currently unaware of any official solution to address this vulnerability.
Vulnerable software versions
SiNVR 3 Central Control Server (CCS): All versions
External links
http://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote authenticated user via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.