Vulnerability identifier: #VU54953
Vulnerability risk: High
CVSSv4.0: 6.1 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber]
CVE-ID: CVE-2021-34312
CWE-ID:
CWE-122
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
JT2Go
Server applications /
Virtualization software
Teamcenter Visualization
Other software /
Other software solutions
Vendor: Siemens
Description
The vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to a boundary error in the Tiff_loader.dll library when parsing TIFF files. A remote attacker can pass specially crafted data to the application, trigger heap-based buffer overflow and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
Mitigation
Install updates from vendor's website.
Vulnerable software versions
JT2Go: before 13.2
Teamcenter Visualization: before 13.2
External links
https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf
https://www.zerodayinitiative.com/advisories/ZDI-21-841/
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.