#VU58079 Input validation error in Siemens products - CVE-2021-31345


Vulnerability identifier: #VU58079

Vulnerability risk: High

CVSSv4.0: 6.8 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber]

CVE-ID: CVE-2021-31345

CWE-ID: CWE-20

Exploitation vector: Network

Exploit availability: No

Vulnerable software:
Nucleus NET
Server applications / Other server solutions
Nucleus Source Code
Server applications / Other server solutions
Capital VSTAR
Server applications / Other server solutions
Nucleus ReadyStart
Server applications / Other server solutions

Vendor: Siemens

Description

The vulnerability allows a remote attacker to compromise the target system.

The vulnerability exists due to the total length of an UDP payload (set in the IP header) is unchecked. A remote attacker can pass specially crafted input to the application and perform a denial of service (DoS) attack or gain access to sensitive information on the system.

Mitigation
Install updates from vendor's website.

Vulnerable software versions

Nucleus NET: All versions

Nucleus Source Code: All versions

Capital VSTAR: All versions

Nucleus ReadyStart: before 4.1.1