#VU84371 Cross-site scripting in Siemens products - CVE-2023-46282


Vulnerability identifier: #VU84371

Vulnerability risk: Low

CVSSv4.0: 1.2 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:U/U:Clear]

CVE-ID: CVE-2023-46282

CWE-ID: CWE-79

Exploitation vector: Network

Exploit availability: No

Vulnerable software:
Opcenter Quality
Server applications / SCADA systems
SINUMERIK Integrate RunMyHMI /Automotive
Server applications / SCADA systems
Totally Integrated Automation Portal (TIA Portal)
Other software / Other software solutions
User Management Component (UMC)
Other software / Other software solutions
SIMATIC PCS neo
Web applications / Other software

Vendor: Siemens

Description

The disclosed vulnerability allows a remote attacker to perform cross-site scripting (XSS) attacks.

The vulnerability exists due to insufficient sanitization of user-supplied data in the web interface. A remote attacker can trick the victim to follow a specially crafted link and execute arbitrary HTML and script code in user's browser in context of vulnerable website.

Successful exploitation of this vulnerability may allow a remote attacker to steal potentially sensitive information, change appearance of the web page, perform phishing and drive-by-download attacks.

Mitigation
Install updates from vendor's website.

Vulnerable software versions

Opcenter Quality: All versions

SINUMERIK Integrate RunMyHMI /Automotive: All versions

Totally Integrated Automation Portal (TIA Portal): 14 - 18

SIMATIC PCS neo: before 4.1

User Management Component (UMC): before 2.11.2


External links
https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf


Q & A

Can this vulnerability be exploited remotely?

Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.

Is there known malware, which exploits this vulnerability?

No. We are not aware of malware exploiting this vulnerability.


Latest bulletins with this vulnerability