Vulnerability identifier: #VU94200
Vulnerability risk: Low
CVSSv4.0: 2 [CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Clear]
CVE-ID: CVE-2023-32737
CWE-ID:
CWE-502
Exploitation vector: Local
Exploit availability: No
Vulnerable software:
Totally Integrated Automation Portal (TIA Portal)
Other software /
Other software solutions
SIMATIC STEP 7 Safety
Server applications /
SCADA systems
Vendor: Siemens
Description
The vulnerability allows a local user to execute arbitrary code on the target system.
The vulnerability exists due to insecure input validation when processing serialized data within the .NET BinaryFormatter. A local administrator can pass specially crafted data to the application and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
Mitigation
Install updates from vendor's website.
Vulnerable software versions
Totally Integrated Automation Portal (TIA Portal): before 18
SIMATIC STEP 7 Safety: before 18
External links
https://cert-portal.siemens.com/productcert/html/ssa-313039.html
Can this vulnerability be exploited remotely?
No. This vulnerability can be exploited locally. The attacker should have authentication credentials and successfully authenticate on the system.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.