Vulnerability identifier: #VU97161
Vulnerability risk: High
CVSSv4.0: 8.1 [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/U:Amber]
CVE-ID: CVE-2024-33698
CWE-ID:
CWE-122
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
SIMATIC Information Server
Hardware solutions /
Firmware
SIMATIC PCS neo
Web applications /
Other software
SINEC NMS
Server applications /
Remote management servers, RDP, SSH
Totally Integrated Automation Portal (TIA Portal)
Other software /
Other software solutions
Vendor: Siemens
Description
The vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to a boundary error in the integrated UMC component. A remote attacker can pass specially crafted data to the application, trigger a heap-based buffer overflow and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
Mitigation
Install update from vendor's website.
Vulnerable software versions
SIMATIC Information Server: 2022 - 2024
SIMATIC PCS neo: 4.0 - 5.0
SINEC NMS: All versions
Totally Integrated Automation Portal (TIA Portal): 16 - 19
External links
https://cert-portal.siemens.com/productcert/html/ssa-039007.html
https://www.tenable.com/security/research/tra-2024-37-0
https://www.cisa.gov/news-events/ics-advisories/icsa-24-256-03
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?