Vulnerability identifier: #VU84685
Vulnerability risk: High
CVSSv3.1: 9 [CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:U/RC:C]
CVE-ID:
CWE-ID:
CWE-502
Exploitation vector: Network
Exploit availability: No
Vulnerable software:
ViewPower Pro
Server applications /
SCADA systems
Vendor: Voltronic Power
Description
The vulnerability allows a remote attacker to execute arbitrary code on the target system.
The vulnerability exists due to insecure input validation when processing serialized data within the RMI interface on port 41009/TCP. A remote attacker can pass specially crafted request to the application and execute arbitrary code on the target system.
Successful exploitation of this vulnerability may result in complete compromise of vulnerable system.
Mitigation
Cybersecurity Help is currently unaware of any official solution to address this vulnerability.
Vulnerable software versions
ViewPower Pro: 2.0-22165
External links
http://www.zerodayinitiative.com/advisories/ZDI-23-1876/
http://www.cisa.gov/news-events/ics-advisories/icsa-24-023-03
Can this vulnerability be exploited remotely?
Yes. This vulnerability can be exploited by a remote non-authenticated attacker via the Internet.
Is there known malware, which exploits this vulnerability?
No. We are not aware of malware exploiting this vulnerability.